ENGINEERING WORKBENCH/HEX PERFORMANCE
LoadingBUILD 2.0
CALCULATION MODULE · TWO-STREAM HEAT EXCHANGER

Single HEX modelling (Fzz)

Single-exchanger calculations, temperature profiles and Fzz formula selection.

The Heat Exchanger Modelling Framework (Fzz) uses mathematically simplified, equivalent forms of the established ε–NTU relations for counterflow and parallel flow. A formula selector uses the HEX configuration and operating point to choose the formula actually used: general exponential relations, the equal-capacity formula, reservoir formulas or transitions. Approximations are applied within a user-selected relative H tolerance. Calculate heat transfer and outlet temperatures, compare configurations and inspect the active formula. The overview and diagnostic maps show the formula families and the current operating region.

Fzz introduction · Open segmented HEX modelling · Comparison with LMTD and ε–NTU
CALCULATION STATUS Ready to calculate
PRIMARY SOLVER Fzz · Closed-form calculation
HEAT TRANSFER RATE
—kW
From stream 1 to stream 2
OUTLET · STREAM 1
—°C
T₁,out · selected formula
OUTLET · STREAM 2
—°C
T₂,out · selected formula
TRANSFER FACTOR
—W/K
Fzz / H · applied formula
02 / VISUALISATION

Temperature & heat transfer

Local temperature profiles of both streams

Stream 1 Stream 2Temperatures along the heat transfer coordinate
Loading calculation…
03 / COMPARISON

Counterflow vs. parallel flow

QuantityCounterflowParallel flow
Loading calculation…
Both configurations use identical boundary conditions and UA. Effectiveness ε = H/min(C₁,C₂) is reported only as a conventional comparison quantity; it is not used to calculate H.
04 / SECOND LAW

Entropy & exergy

ENTROPY GENERATION
—W/K
EXERGY DESTRUCTION
—kW
Ṡgen = C₁ ln(T₁,out/T₁,in) + C₂ ln(T₂,out/T₂,in)
ĖD = T₀ · Ṡgen
(all temperatures in kelvin)
05 / MODEL & VERIFICATION

Numerical and physical checks

Loading calculation…
06 / CALCULATION METHODS

Equivalent formulas and calculation routes

The Fzz heat-transfer formulas are mathematically simplified forms of the established ε–NTU relations for ideal counterflow and parallel flow. They express the same model in the original stream quantities; they are not a separate physical theory or a claim of entirely new heat-transfer relations. The framework organises these equivalent formulas and their limiting cases through a selector based on HEX configuration and operating point.

  • The Heat Exchanger Modelling Framework (Fzz) uses these simplified, explicit counterflow and parallel-flow relations across the ideal steady-state model domain: positive stream capacity rates, nonnegative UA, either capacity-rate ordering, equal capacities, and either direction of heat transfer. Equal-capacity, zero-UA and zero-driving-temperature cases are included. Large-UA and reservoir behaviour follow as limits. The selector identifies the flow relation and relevant limiting case from the configuration, UA and stream capacity rates. Heat transfer and both outlet temperatures then follow directly from the supplied inlet conditions.
  • Conventional ε–NTU uses Cr = Cmin/Cmax together with NTU = UA/Cmin. Its formula set distinguishes parallel flow, counterflow with Cr ≠ 1, and the counterflow limit Cr = 1. The ratio is part of this formula set. For the ideal counterflow and parallel-flow relations, its min/max assignment can be eliminated algebraically without changing the result: a redundant intermediate step, described in the framework derivation as a “mathematical loop”, rather than an iterative computation.
  • LMTD can determine unknown outlet temperatures when combined with the stream energy balances and the specified flow arrangement. In the conventional LMTD calculation route, this coupled problem is generally solved iteratively, including for unequal heat capacity rates. Algebraic elimination can instead yield equivalent explicit relations, so iteration is a feature of that calculation route, not an unavoidable mathematical requirement. Equal terminal differences require the continuous logarithmic-mean limit; equal capacity rates produce this condition in ideal counterflow, but not generally in parallel flow.

Coverage versus calculation route. The Fzz framework combines the relations and limiting cases into an inlet-to-outlet calculation. This does not mean that correctly completed LMTD or ε–NTU calculations describe a smaller physical domain: under the same ideal assumptions and with the appropriate limits, they give the same theoretical heat transfer. Both ε–NTU and the Fzz relations can provide closed-form solutions. For finite, unequal capacity rates, selected local approximations may differ from the exact relations within the specified tolerance.

Domain boundary. “Across the operating domain” refers to this ideal, adiabatic, constant-cₚ two-stream model, not every real HEX geometry or transient condition. At zero flow the website reports zero heat transfer but leaves steady-state outlet temperatures undefined. Numerical evaluation is limited to representable inputs and has been verified over the ranges described below.

Conventional definitions and formula cases: ASHRAE Handbook—Fundamentals, Chapter 4, NTU–Effectiveness Analysis and Table 10. The Fzz framework and its numerical verification are described separately below.

Current implementation: configuration and capacity rates propose F1–F5 or a transition formula. The selector uses F3 directly at equal counterflow capacities. Near equality and in reservoir regions, the proposed formula is applied if its relative H error against the general exponential relation is within tolerance and it respects physical bounds; otherwise F2 or F5 is selected. UA therefore participates in the final choice. Default tolerance: 0.001 (0.1%); tolerance zero uses only exact routes. The chosen H determines all results, exports and UA curves. Switching at an acceptance boundary can introduce a small jump within the error tolerance.

07 / COMPLETE FORMULA OVERVIEW

Calculation formula in use

All calculation routes and selector options · active formulas are shown in bold.

08 / COMPLETE COLOUR SCHEME

Formula-family map · selector regions

All selection regions, family colours and the current HEX operating point. Codes such as F2, F3 and F24 identify formulas and transitions; the map shows the proposed region. The applied formula is identified after the accuracy and physical checks.

09 / MODEL SCOPE & EXTENSIONS

Numerical robustness and segmented modelling

Single-contact core and the coupled segment extension.

Formula basis: Roadmap Towards Perfect Heat Exchange; Corrected and Unified LMTD and ε–NTU (2024), §4.4–4.5. The implemented F1–F5 definitions and transition regions follow the corrected family scheme in the companion technical note; this release makes that selector operational with an accuracy guard. It is not a reconstruction of every historical Z-zone rule.

Robust within the supported model. The current steady-state core supports ideal counterflow and parallel flow with constant specific heat capacities. Exponential evaluation using expm1, a separate equal-capacity formula, accuracy checks and physical-bound checks address small and large UA and nearly equal or strongly unequal heat capacity rates. These provisions support robust evaluation within the valid, representable input range; they do not establish unconditional stability for every HEX configuration or operating condition.

Segmented modelling. Closed-form segment relations can form the building blocks of an extended model with a separate local UjAj for each segment. Segment connections must conserve energy and respect the flow arrangement. Counterflow coupling can require a system of algebraic equations; temperature-dependent properties can introduce iteration. A closed-form local relation does not by itself make the complete network solution explicit.

Residence time and thermal mass. The separate segmented HEX module adds individual transport delays and fluid buffer inventories to local Fzz contacts. Its contact/delay model is a reduced network approximation, with explicit residence times. Wall heat capacity requires additional storage balances and separate fluid-to-wall heat transfer paths. Such a segmented model can use ODEs or DAEs without a general-purpose PDE solver. Analytical time updates are possible for suitable linear submodels, but accuracy and stability of the coupled model must still be verified through conservation checks, segment and time-step refinement, and comparison with reference solutions or measurements.

Implementation note. The production core uses exponential and rational closed-form relations, without tanh, an explicit power series or an iterative outlet-temperature solver. The built-in expm1 function evaluates exp(x) − 1 accurately for small arguments. An exact exponential reference is evaluated to check approximations, so no speed advantage is claimed. The time interval in the original single-HEX calculator only calculates E = Q̇Δt. Residence times and fluid buffer storage are configured separately in the segment module.

Alternative numerical evaluation. An algebraically equivalent tanh formulation with a local series was tested previously. It is retained as an offline comparison implementation, not used by the active website solver.

Numerical model verification; not experimental validation. The exponential reference and the active selector are checked separately against reference calculations. Conventional ε–NTU quantities retained in JSON exports are labelled as reference diagnostics only. Accepted selector formulas determine the primary results; the displayed deviation is the error in H relative to the exact ideal model.