TezzitHeat exchanger engineering

HEAT EXCHANGER MODELLING FRAMEWORK

Fzz. From one exchanger
to coupled segments.

Calculate heat transfer and outlet temperatures. Explore local temperature profiles and how a temperature change travels through a heat exchanger.

The Fzz framework organises equivalent, explicit forms of the established counterflow and parallel-flow ε–NTU relations. A selector chooses the applicable formula or limiting case from the flow arrangement, capacity rates and UA, with an accuracy check for approximations.

Q˙=Fzz·(T1,in−T2,in)Fzz is the heat-transfer factor [W/K], determined from C₁ = ṁ₁cₚ₁, C₂ = ṁ₂cₚ₂ and UA.

SINGLE HEX

One exchanger

Set inlet temperatures, flow rates, heat capacities and UA. Compare counterflow and parallel flow, inspect the active Fzz formula and explore temperature profiles.

Open single-HEX modelling

SEGMENTED HEX

Connected local models

Couple 1–24 Fzz segments. Assign local OHTC Uⱼ, area Aⱼ and a residence time for each stream. Calculate the stationary network or follow an inlet temperature step through the segments.

Open segmented HEX modelling